ccs,pf series,PF-A4048-2,PF-A16048-4
Welcome to JIDIEN
Product Introduction 產品資訊

CCS LED光源 PF Series 控制器

Light controller
CCS Multi-functional Control Units for High Power Strobe LED Light Units.
Brightness can be adjusted through output voltage control.
Parameter registration for individual inspections is possible.
  • Model name

    PF-A4048-2
    PF-A16048-4

    Lighting method

    Strobe lighting

    Drive method

    Constant-voltage system

    Intensity control method

    Variable-voltage control, Strobe time control

    Number of channels

    PF-A4048-2: 2 channels, PF-A16048-4: 4 channels

    Number of output connectors

    PF-A4048-2

    L1: 2, L2: 1

    Number of output connectors

    PF-A16048-4

    L1: 2, L2: 2, L3: 2, L4: 2

    Applicable Light Unit (ratings)

    High Power Strobe Light Units from CCS

    Output voltage settings

    Manual

    Operation on the front panel

    512 levels

    Output voltage settings

    External

    Command input via TCP/IP or

    UDP/IP comm.

    Signal input through parallel port

    Strobe time settings

    Manual

    Operation on the front panel

    PF-A4048-2: 1 to 100 μs

    (in steps of 0.1 μs) PF-A16048-4: 1 to 500 μs*

    Strobe time settings

    External

    Command input via TCP/IP or

     UDP/IP comm.

    Signal input through parallel port

    Lighting delay settings

    Manual

    Operation on the front panel

    0 to 100 μs

    (in steps of 0.1 μs)

    Lighting delay settings

    External

    Command input via TCP/IP or

    UDP/IP comm.

    Signal input through parallel port

    Input power

    100 to 240 VAC (+10%, -15%), 50/60 Hz

    Power consumption (typ.)

    PF-A4048-2: 65 VA, PF-A16048-4: 140 VA

    Inrush current (typ.)

    PF-A4048-2: 15 A (at 100 VAC), 36 A (at 240 VAC) from a cold start

    Inrush current (typ.)

    PF-A16048-4: 17 A (at 100 VAC), 40.8 A (at 240 VAC) from a cold start

    Ground leakage current

    3.5 mA max. (264 VAC, 60 Hz, with no load)

    Output voltage (ratings)

    High intensity range: 33 to 48 VDC Low intensity range: 12 to 48 VDC

    Output current (peak)

    PF-A4048-2: 43.2 A total for 2 channels (21.6 A/connector), PF-A16048-4: 172.8 A total for 4 channels (21.6 A/connector)

    Insulation withstand voltage (input-output, input-FG)

    1500 VAC for one minute, Cutoff current: 10 mA,

    500 VDC, 20 MΩ min.

    Overvoltage category

    Category II

    Operating environment

    Temperature: 0 to 40°C, Humidity: 20% to 85% (with no condensation)

    Altitude: 2,000 m max., Protective ground class: Class I, Pollution degree: 2, Indoor use only

    Storage environment

    Temperature: −20 to 60°C, Humidity: 20% to 85% (with no condensation)

    Cooling method

    Forced air cooling

    CE marking

    Safety standard: Conforms to EN 61010-1, EMC standard: Conforms to EN61000-6-2 and EN61000-6-4

    Environmental regulations

    RoHS compliant

    Material, coating, and surface processing

    Steel sheet, Cover thickness: 1.6 mm, Chassis thickness: 1.0 mm, Black (half matte)

    Weight

    PF-A4048-2: 1,900 g max., PF-A16048-4: 3,300 g max.

    Accessories

    Instruction guide, 2-m-long 3-prong AC power cord with ground terminal